i) Mode and activation time for output #1 - programming code 51
In the default setting, output #1 for the door opener is activated for a duration of 5 seconds if a
valid user code or visitor code is used.
If desired, the duration can be set in the range of 1 - 99999 seconds (max. therefore a little more
than 27 hours) and also a timer can be realised.
The output can also operate in toggle mode. This means that you can activate the output
permanently or deactivate it again. Use this mode to control (arm/disarm) an alarm system.
In toggle mode, the output remains activated until you deactivate it again. Each valid
user code toggles the status of the respective output.
We recommend that you only use toggle mode in combination with an alarm system
or a "Fail-Safe" door opener.
"Fail-Safe" door openers release the latch when the power is removed (non-standard
door opener type, used for emergency exit doors so that the door opens in the event
of a power cut).
"Fail-Secure" door openers (releases the latch when power is supplied; used for
normal front doors) may overheat when the output is permanently enabled.