Programming example: Setting output #1 to toggle mode
When a valid user code is entered, the corresponding output stays activated until a user code is
entered again. Use this mode to control (arm/disarm) an alarm system.
(a)
(b)
(a) Programming code 51 for output #1
(b) Code "0" = set output to toggle mode; output is toggled when a valid user code (or visitor
code) is entered.
(c) Save programming (code lock emits two beep tones and the centre LED flashes twice
orange)
Resetting active output #1 with the superuser code
If the activation time of output #1 is set higher and the output is currently active, it can be reset
manually at any time with the superuser code. In this way, the output is deactivated again before
the time has elapsed. In principle, this is the same function as activating/deactivating output #1
with the superuser code (see Chapter 14. e).
Example: The superuser code was set to "6789":
j) Real-time clock - programming code 55
This 24-hour real-time clock provides the daily time base for all time-based functions for output
#1 (door opener).
If you do not wish to use any time-based functions for output #1, setting the real-time
clock is not mandatory.
After a power failure, the real-time clock will no longer run and must be reprogrammed.
If times are programmed under programming code 56, the code lock will emit 3 quick
beep tones every 5 seconds after a power failure until the clock is reprogrammed.
We recommend reprogramming the clock every 3 - 6 months or when a time
discrepancy is detected to ensure accuracy.