13. "DAP" mode

The "DAP" mode is used to activate programming mode if you forget the master code you have
programmed.
By default, the master code is set to "0000".
Proceed as follows:
• Disconnect the code lock for at least 1 minute from power supply.
• Switch on power supply again. The code lock is for 1 minute in a special mode, in which you
can activate programming mode with the help of the DAP code.
The piezo buzzer emits a continuous beep tone and the centre LED flashes orange.
• Press the door opener button once (the button connected to screw terminals 8 "EG IN" and
GND (-) (screw terminals 2).
The piezo buzzer emits two short beep tones and then stops. The centre LED continues to
flash orange.
• Now enter the DAP code
• Confirm input with the
• The code lock is now in programming mode.
• Set a new master code. Refer to Chapter "14. d) Programming the master code - programming
code 01".
• To exit programming mode, press the
LED should now flash slowly orange (normal mode). If the Wi-Fi module is installed but still
configured, the LED flashes quickly red in normal mode.
DAP mode is basically only used to activate programming mode if you have forgotten
the master code.
The DAP code is permanently programmed in the system and cannot be changed.
The code lock automatically switches to normal mode 1 minute after it is switched on
if the door opener button is not pressed and DAP code is entered. To restore the code
lock to DAP mode, disconnect from power supply and start again.
.