5.7 Changing the coaxial cable length

Valid for versions with remote amplifier.
This setting makes it possible to configure the coaxial cable length between the sensor head and
process connection.
Configuration
Predefined coaxial cable length (1,000 mm, 2,000 mm, or 3,300 mm)
Log into expert mode (see Chapter "5.1 Expert mode")
Configure the coaxial cable length in the EXPRT-Config-CblLen menu (1,000 to 3,300 mm)
Note:
Only the following configurations are permitted:
Coaxial cable length [mm]
1,000
2,000
3,300

5.8 Activating the display lock

To prevent the sensor from being tampered with, password protection can be activated for the
display.
When the protection is active, the expert password (000537) must be entered before the menu
can be accessed.
The menu is only unlocked once the correct password is entered.
Configuration
Log into expert mode (see Chapter "5.1 Expert mode")
The protection can be (de)activated via the EXPRT-Config-Lock menu.
Note:
The user is logged out again after 5 minutes of inactivity.
When the display is locked, only the configured measured value display (DspVal) can be seen

5.9 Selecting the display unit (millimeter/inch)

This setting makes it possible to display and configure all length measurements in either millime-
ters or inches.
Configuration
Log into expert mode (see Chapter "5.1 Expert mode")
Set the unit in the EXPRT-Config-Unit menu (mm/inch)
88
8014825/YE12/2014-09-15 © SICK AG • Level sensors • Germany • Subject to change without notice
5 Advanced functions
Max. probe length [mm]
Foam mode inactive
4,000
3,000
1,000
LFP Cubic
Foam mode active
2,000
1,500
500