Herunterladen Inhalt Inhalt Diese Seite drucken

Mechanics/Materials; Electrical Connection Values - Sick Tdr Betriebsanleitung

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

EN
Operating instructions

9.5 Mechanics/materials

Wetted parts
Process connection
Housing material
Max. probe load
Enclosure rating
Weight
Coaxial cable insulation

9.6 Electrical connection values

Supply voltage
1) 2)
Current consumption
Initialization time
Protection class
Connection type
Hysteresis
Output signal
1)
Signal voltage HIGH
Signal voltage LOW
Output current
Inductive load
Capacitive load
Temperature drift
Output load
Lower signal level
Upper signal level
EMC
All connections are reverse polarity protected. All outputs are overload and short-circuit protected.
1)
Use an energy-limited circuit for power supply as per UL61010-1 3rd Ed., Section 9.3
2)
110
8014825/YE12/2014-09-15 © SICK AG • Level sensors • Germany • Subject to change without notice
9 Technical data
1.4404, PTFE
G 3/4 A,
3/4'' NPT
Plastic PBT
≤ 6 Nm
IP67: EN 60529
Max. 1.3 kg
PVC
12 V DC to 30 V DC
≤ 100 mA at 24 V without output load
≤ 5 s
III
M12 x 1 (5-pin)
M12 x 1 (8-pin)
Min. 3 mm, freely configurable
4 mA to 20 mA / 0 V to 10 V automatically switchable
depending on output load
1 PNP transistor output (Q1) and 1 PNP/NPN transistor
output (Q2) switchable, or
1 PNP transistor output (Q1) and 3 PNP/NPN transistor
outputs (Q2 to Q4) switchable (depending on type)
Uv –2 V
≤ 2 V
< 100 mA
< 1 H
100 nF
< 0.1 mm/K
4 mA to 20 mA < 500 ohms at Uv > 15 V
4 mA to 20 mA < 350 ohms at Uv > 12 V
0 V to 10 V > 750 ohms at Uv ≥ 14 V
3.8 mA to 4 mA
20 mA to 20.5 mA
EN 61326-1:2006, 2004/108/EC
LFP Cubic
1)
1)
Inhaltsverzeichnis