Remontagem da cobertura da polia
Aplique LOCTITE 243 na rosca dos 2 parafusos originais (A1) e dos
parafusos originais (A2).
Posicione a cobertura da polia original (A) na tampa do alternador
(B) e encoste os 2 parafusos (A1) e o parafuso (A2), como
mostrado na figura.
Aperte os 2 parafusos (A1) e o parafuso (A2) ao binário indicado.
12
B
Reassembling the pulley cover
Apply LOCTITE 243 on the thread of no.2 original screws (A1) and
original screw (A2).
Position the original pulley cover (A) on the generator cover (B) and
start no.2 screws (A1) and screw (A2) in their thread, as shown in
the figure.
Tighten no. 2 screws (A1) and screw (A2) to the specified torque.
6 Nm ± 10%
A1
A
A2
6 Nm ± 10%
ISTR 803 / 00