Minimum activation voltage [V]
Maximum deactivation voltage [V]
Maximum admissible voltage [V]
Current absorption at 12V [mA]
N.B. Inputs can be controlled with both polarities (positive or negative with respective return to earth)
2.3.4
Connection of the user outputs
The user outputs are available only in type M/T and T/T inverters.
The wiring diagram and the electrical characteristics of the outputs are shown below.
Type of contact
Max. admissible voltage [V]
Max. admissible current [A]
2.3.5
Connection of the remote sensor
2.3.6
Connection of the multi-inverter communication
The multi-inverter communication takes place through the connectors indicated in Table 11. The connection must be
made by connecting together the corresponding pins on different inverters (e.g. pin 1 of inverter A on in 1 of inverter B,
etc.). It is recommended to use twisted and shielded cable. The shield must be connected on both sides to the central
pin of the connector.
Maximum recommended length of the communication cable between two inverters L: 5m.
Total maximum recommended length (sum of the lengths of all the communication cables): 20m.
Input characteristics for type M/T and T/T inverters
Table 8: Input specifications
User outputs wiring diagram
Type of
Name of
inverter
connector
M/T
J13
T/T
J6
Table 9: Output connection
Figure 5: Output connection
Output contact specifications
Table 10: Output contact specifications
Connection of the remote sensor
Type of inverter
M/T
T/T
M/M
Table 11: Connection of the remote pressure sensor
ENGLISH
DC inputs [V]
8
2
36
3,3
Pin
Output
Out 1
1-2
3-4
Out 2
Out 1
1-2
3-4
Out 2
NO
250
5
-> resistive load
2,5 -> inductive load
Name of connector
J8
J10
J6
64
AC inputs 50-60 Hz [Vrms]
8
1,5
24
3,3