Herunterladen Inhalt Inhalt Diese Seite drucken

Connecting The Suction And Discharge Lines; Electrical Connections; Versions With Mains Plug; Versions Without Mains Plug - Grundfos DMX 226 Montage- Und Betriebsanleitung

Vorschau ausblenden Andere Handbücher für DMX 226:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 66

5.5 Connecting the suction and discharge lines

Warning
All lines must be free from strain!
Only use the prescribed line types!
Connect the suction line to the suction valve.
– Install the suction line in the tank so that the foot valve
remains 5 to 10 mm above the bottom of the tank or the
possible level of sedimentation.
Connect the discharge line to the discharge valve.
Connection of hose lines
Push the hose firmly onto the connection nipple and,
depending on the connection, secure using a connection
counterpart or hose support clip.
Fit the gasket.
Screw onto the valve using the union nut.
Fig. 13 Connection of hose lines
Connection of DN 20 pipe lines
Depending on the pipe material and connection, glue it (PVC),
weld it (PP, PVDF or stainless steel) or press it in (stainless
steel).
Fit the gasket.
Screw onto the valve using the union nut.
Fig. 14 Connection of DN 20 pipe lines
Connection of DN 32 pipe lines
Depending on the pipe material, fit the pipe to the welding
neck flange and weld it (stainless steel) or insert it into the
headed bush and weld it (PP, PVDF).
Fig. 15 Connection of DN 32 pipe lines
20
Using a dosing controller
Screw the dosing controller onto the discharge valve.
Connect the discharge line to the dosing controller.
Fig. 16 Dosing controller

6. Electrical connections

Make sure that the pump is suitable for the electricity supply on
which it will be used.
Warning
Electrical connections must only be carried out by
qualified personnel!
Disconnect the power supply before connecting the
power supply cable and the relay contacts!
Observe the local safety regulations!
Warning
The pump housing must only be opened by
personnel authorised by Grundfos!
Warning
Protect the cable connections and plugs against
corrosion and humidity.
Only remove the protective caps from the sockets
that are being used.
The power supply must be electrically isolated from
Caution
the signal inputs and outputs.
The pump is switched off by switching off the power
supply.
Note
Do not switch on the power supply until the pump is
going to be started.

6.1 Versions with mains plug

Insert the mains plug in the mains socket.

6.2 Versions without mains plug

Connect the motor according to the wiring diagram in the
terminal box.
Observe the direction of rotation!
A motor protector, adjusted to the rated motor
current, must be provided by the customer. This is
also necessary for versions with AR control unit!
Caution
When the pump is used with a frequency converter,
the jumpers in the terminal box have to be set
according to the converter voltage.
The jumpers of three-phase motors are factory-set
for star connection.
2 mm

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis