10.3.13.2

Metering monitoring / Stop pump

10.3.13.3

Metering monitoring / Strokes

10.3.13.4
Metering monitoring / Deviation (only at E60
A tolerance in % is set under "deviation".
The actual incoming pulse rate recorded by the oval gear meter within the pump interval to
be monitored (see chapter
pulse rate defined during calibration.
If this comparison results in a deviation that is greater than the % value configured under
"deviation", a "metering monitoring alarm" is triggered.
This function can only be selected if a dongle box is connected and configuration/oval
NOTE
gear meter (see chapter 10.3.11) has been activated.
417101441_EMP_III_E60.docx
"Configuration/Strokes") is compared with the target
10.3.13.3
- 107 -
Fig. 10.35 Metering monitoring / Stop pump
The "stop pump" function is used to
set whether or not the pump should
be stopped if a "metering
monitoring alarm" is triggered.
- Pump is not stopped
when a "metering monitoring alarm"
is triggered. (Default setting)
✓ Pump is stopped
when a "metering monitoring alarm"
is triggered.
Fig. 10.36 Metering monitoring / Strokes
The "strokes" option indicates the
stroke interval to be monitored.
Setting range: 0 – 100
Default setting = 10
PLUS
PLUS
& OGM or OGM
Fig. 10.37 Metering monitoring / Deviation (only at E60
PLUS
OGM or OGM
)
Setting range: 0-100%
Default setting = 20 %
)
PLUS
&