BMD 1E _ A- _ _ _ _ / _ _ _ -A _ 502A-LV _ _ _ -KS288
Microwave Positioning Sensor
1
Notes to the user
1.1
Validity
This guide describes the design, working principle
and setup options for the BMD microwave positioning
sensor with analog interface. It applies to types
BMD 1EAA- _ _ _ _ / _ _ _ -A _ 502A-LV_ _ _-KS288 and
BMD 1EBA- _ _ _ _ / _ _ _ -A _ 502A-LV_ _ _-KS288
(see Type code on page 16).
The guide is intended for qualified technical personnel.
Read this guide before installing and operating the
microwave positioning sensor.
1.2
Symbols and conventions
Individual instructions are indicated by a preceding
triangle.
► Instruction 1
Action sequences are numbered consecutively:
1. Instruction 1
2. Instruction 2
Note, tip
This symbol indicates general notes.
1.3
Scope of delivery
–
Microwave positioning sensor BMD
–
Condensed guide
The document Design specifications for
constructing the hydraulic cylinder can be
downloaded from the Internet at
www.balluff.com or requested via e-mail from
service@balluff.de.
1.4
Approvals and markings
Patents:
WO 2011/080200 A1
–
–
US 10 320 049 B2
–
DE 10 2016 106 747 B4
–
DE 10 2016 118 025 A1
The patents were awarded in connection with this product.
E1 mark:
The sensor meets the requirements of the ECE-R10
regulation (radio interference suppression).
The CE Mark verifies that our products
meet the requirements of the current
EMC Directive.
4
english
The microwave positioning sensor meets the requirements
of the following product standard:
–
EN 61326-2-3 (noise immunity and emission)
Emission tests:
– RF emission
EN 55011
Noise immunity tests:
– Static electricity (ESD)
EN 61000-4-2
– Electromagnetic fields (RFI)
EN 61000-4-3
– Electrical fast transients
(burst) EN 61000-4-4
– Surge
EN 61000-4-5
– Conducted interference
induced by high-frequency fields
EN 61000-4-6
Compatibility tests (EMC Directive):
– Road vehicles
– Electrostatic Discharge (ESD)
– Electrical Testing
More detailed information on the guidelines,
approvals, and standards is included in the
declaration of conformity.
EMC properties
The ensured EMC properties can only be
achieved if the BMD microwave positioning
sensor is installed completely in a metallic
closed cylinder filled with oil.
Severity level 3
Severity level 3
Severity level 3
Severity level 2
Severity level 2
ISO 7637-2/3
ISO 10605
ISO 16750