Nominal gross heating power
Nominal net heating power
Air flow
Air compression
Slow combustion at nominal power
Combustion durability at reduced power
One-time fuel (timber) load
Efficiency at nominal power
CO emission (13% O
)
2
Exhaust fumes mass stream
Mean exhaust fumes temperature
Distance of the inflammable parts from the device
Distance of inflammable parts from the side of the hot air outlet from the
device
- at nominal power
Chimney draught:
- at reduced load
- large-size (width x height x depth)
Dimensions:
- exhaust fume outlet diameter
Heater mass:
- type
Fuel:
- humidity
Rated voltage
Rated current
TECHNICAL DATA
CT50P
50,0 kW
30,2 kW
1200 m
/h
3
40 Pa
1h22min
4h12min
~15,0 kg
60,74%
0,5%
38,89 [g/s]
360°C
1,50 m
2,00 m
12 Pa
6 Pa
1315 x 1190 x 775 mm
φ
148 mm
z
302 kg
Clearing of deciduous
trees: beech,
hornbeam, oak, alder,
birch etc.
<20%
230V ~50Hz
0,6 A
en