7. Descriptions of the operating characteristics
7.3 Monitoring output 2, 3-term control (heating/cooling)
Monitoring output
EN
Monitoring output 1,
relay (OUT1)
Monitoring output 1,
logic level (OUT1)
Monitoring output 1
Analogue current
signal (OUT1)
Monitoring output
2, electronic relay
(OUT2)
Monitoring output 2,
logic level (OUT2)
Monitoring output 2
Analogue current
signal (OUT2)
LED monitoring
output 1 (OUT1)
LED monitoring
output 2 (OUT2)
68
P band heating
ON
Heating
OFF
Switching status, dependent upon the control deviation
+
+
DC 12 V
Switching status, dependent upon the control deviation
+
+
DC 20 mA
Changes will occur continuously in accordance with the control deviation
+
+
Changes will occur continuously in accordance with the control deviation
ON
OFF
WIKA operating instructions models CS6S, CS6H, CS6L
P band cooling
Set point
+
DC 12/0 V
+
DC 20 ... 4 mA
Switching status, dependent upon the control deviation
+
DC 12/0 V
DC 0 V
Switching status, dependent upon the control deviation
+
DC 20 ... 4 mA
DC 4 mA
ON
Cooling
OFF
DC 0 V
DC 4 mA
+
DC 12 V
+
DC 20 mA
OFF
ON