Herunterladen Inhalt Inhalt Diese Seite drucken

Hirschmann PowerMICE Anwenderhandbuch Seite 53

Vorschau ausblenden Andere Handbücher für PowerMICE:
Inhaltsverzeichnis
Multiple Ringe
enable
configure
sub-ring 1 operation enable
Operation set to Enabled
exit
show sub-ring
Ring ID: 1
Mode of Switch (administrative setting)... manager
Mode of Switch (real operating state)..... manager
Port Number............................... 1/9,
Protocol.................................. Standard MRP
MRP Domain ID.............................
255.255.255.255.255.255.255.255.255.255.255.255.255.255.255.255Ri
ng Name.................................. Test
Partner MAC.............................. 02:E3:00:1B:00:09
VLAN ID.................................. 0 (No VLAN)
Operation................................ Enabled
General Operating States:
SRM Setup Info (Config. Failure)......... No Error
Manager-related Operating States:
Ring State............................... Open
Redundancy Guaranteed.................... No
copy system:running-config
nvram:startup-config
 Haben Sie beide SRM und ggf. die im Sub-Ring eingebundenen Geräte
konfiguriert, schließen Sie die redundante Strecke des Sub-Rings.
UM Redundanzkonfiguration L3P
Release 7.1 12/2011
Wechsel in den Privileged-EXEC-Modus.
Wechsel in den Konfigurationsmodus.
Schaltet den Sub-Ring mit der Sub-Ring-ID 1 ein.
Wechsel in den Privileged-EXEC-Modus.
Zeigt den Status für alle Sub-Ringe auf diesem
Gerät an.
Die aktuelle Konfiguration in den nichtflüchtigen
Speicher sichern.
4.1 Sub-Ring
State: Forwarding