16 Maintenance plan

Always comply with the following maintenance intervals in order to ensure problem-free operation.
Attention! The fuel must be filled in before the device is used for the first time.
Component
Checking
the
Check
air filter
Clean
Spark plug
Check and adjust
Replace
Spark plug con-
Clean
nector
Cooling fins
Test
Fasteners such
Check (tighten if
as screws and
necessary)
nuts
Seals
of
the
Check
connecting ele-
place if necessary
ments
Idle
Check and adjust
Combustion
Clean
chamber
Fuel
Check
Fuel tank
Check
Fuel line
Check
Attention: Have points "X" carried out only by an authorised specialist company.

17 Troubleshooting

The following table shows fault symptoms and describes remedial measures in the event of your product failing to work
properly. If you cannot localise and rectify the problem with this, please contact your service workshop.
Troubleshooting during commissioning
Fault
No ignition spark
Spark plug
Other
Weak spark
Compression
Troubleshooting during operation
Fault
Engine does not come
up to speed
Carburettor leaking
Before every
use
X
X
and
re-
X
Possible cause
Carbon deposit between the spark
plug electrodes
Ignition coil defective, flywheel mag-
net too weak
Too much fuel in the combustion
chamber, bad fuel or water in the
tank
Possible cause
Choke is in the "ON" position.
Movable elements worn out
Exhaust system blocked, no air supply
Ignition spark weak, cylinder head sooty
Carburettor gasket worn
www.scheppach.com
Every 3 months
Every 6 months
or 20h
or 50h
X
X
X
X
Every year (replace if necessary)
Remedy
Set the choke to the "OFF" position.
Replace
Replace exhaust system, check or replace igni-
tion coil, clean/replace air filter.
Set the electrode gap to 0.6 to 0.7 mm.
Contact customer service for this.
Every
12
Every 2 years
months or 100h
or 300h
X
X
X
X
X
X
Remedy
Clean the spark plug.
Set the electrode gap to 0.6 to 0.7
mm.
Replace the spark plug.
Contact customer service for this.
Remove spark plug and allow to dry,
change fuel.
X
GB | 29
Inhaltsverzeichnis
loading

Inhaltsverzeichnis