Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning And Maintenance; Storage - Scheppach Gp1300 Jet Originalbetriebsanleitung

Elektro-gartenpumpe
Vorschau ausblenden Andere Handbücher für GP1300 Jet:
Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the wall
socket.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
The printing of the type designation on the connection
cable is mandatory.
For single-phase AC motors, we recommend a fuse
rating of C 16A or K 16A for machines with a high start-
ing current (from 3000 watts)!
AC motor 230 V~ / 50 Hz
Mains voltage 230 V~ / 50 Hz.
Mains power connection and extension leads must be
3-core = P + N + SL. - (1/N/PE).
Extension leads up to 25 m must have a minimum
cross-section of 1.5 mm².
The mains power connection must be protected with a
max. 16 A fuse.

12. Cleaning and maintenance

m Attention!
Only carry out maintenance, cleaning and adjustment
work when the mains plug is pulled out.
We recommend that you clean the product directly af-
ter every use.
Clean the product at regular intervals using a damp
cloth and a little soft soap. Do not use any cleaning
products or solvents; they could attack the plastic parts
of the product. Make sure that no water can penetrate
the motor.
• For a long service life, we recommend regular check-
ing and care.
22 | GB
• Before extended periods of inactivity or through
the winter, the pump should be thoroughly flushed
through with water, emptied completely and then
stored dry.
• To empty the pump housing, loosen the water drain
screw (8) and tilt the pump slightly.
• If there is a risk of frost the pump must be completely
emptied.
• After longer periods of storage check the pump by
switching on/off briefly in order to check that the ro-
tor turns normally.
• In the event of the pump being jammed connect the
pressure line to the water supply line and remove
the suction hose. Open the water supply line. Switch
the pump on for ca. two seconds several times. This
method rectifies blockages in most cases.
• To clean the pre-filter (7), loosen the pre-filter screw
(6) and remove it. Then clean it with warm water.
Connections and repairs
Connections and repair work on the electrical equip-
ment may only be carried out by electricians.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Motor data - type plate
Service information
With this product, it is necessary to note that the follow-
ing parts are subject to natural or usage-related wear,
or that the following parts are required as consumables.
Wearing parts*: Seals, pre-filter
* may not be included in the scope of delivery!
Spare parts and accessories can be obtained from our
Service Centre. To do this, scan the QR code on the
front page.

13. Storage

Store the product and its accessories in a dark, dry and
frost-free place that is inaccessible to children. The op-
timum storage temperature is between 5 and 30 ˚C.
Keep the tool in its original packaging. Cover the tool
to protect it from dust or moisture. Store the operating
manual with the tool.
www.scheppach.com
Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Gp1300 jet se59094039015909403917

Inhaltsverzeichnis