Rmon-Alarm Modify - Hirschmann Hios-2S Rspl Referenzhandbuch

Command line interface (cli) (rail switch power lite)
Inhaltsverzeichnis
Remote Monitoring (RMON)

46.1.5 rmon-alarm modify

Modify RMON alarm parameters.
Mode: Global Config Mode
Privilege Level: Operator
Format: rmon-alarm modify <P-1> [mib-variable <P-2>]
[rising-threshold <P-3>] [falling-threshold <P-4>]
[interval <P-5>] [sample-type <P-6>] [startup-alarm
<P-7>] [rising-event <P-8>] [falling-event <P-9>]
[mib-variable]: Enter the alarm mib variable.
[rising-threshold]: Enter the alarm rising threshold.
[falling-threshold]: Enter the alarm falling-threshold.
[interval]: Enter the alarm interval in seconds over which the data is
sampled.
[sample-type]: Enter the alarm method of sampling the selected variable.
[startup-alarm]: Enter the alarm type.
[rising-event]: Enter the alarm rising-event index.
[falling-event]: Enter the alarm falling-event index.
Parameter Value
1..150
P-1
string
P-2
1..2147483647
P-3
1..2147483647
P-4
1..2147483647
P-5
absoluteValue
P-6
deltaValue
522
Meaning
Enter an index that uniquely identifies an
entry in the alarm table.
Enter an object identifier of the particular
variable to be sampled, max. 32 characters.
Enter the rising threshold for the sampled
statistic.
Enter the falling threshold for the sampled
statistic.
Enter the interval in seconds over which the
data is sampled and compared with the rising
and falling thresholds.
Variable is compared directly with the th-
resholds.
Variable is subtracted from the current
value and the difference compared with the
thresholds.
46.1 rmon-alarm
RM CLI HiOS-2S RSPL
Release 5.0 05/2015