Herunterladen Inhalt Inhalt Diese Seite drucken

Precision Time Protocol (Ptp); Ptp; Ptp Operation; Ptp Clock-Mode - Hirschmann Rm Cli Hios-2S Rsps Referenzhandbuch

Command line interface; rail switch power smart
Inhaltsverzeichnis

Precision Time Protocol (PTP)

41 Precision Time Protocol (PTP)
41.1

ptp

Enable or disable the Precision Time Protocol (IEEE 1588-2008).
41.1.1

ptp operation

Enable or disable the Precision Time Protocol (IEEE 1588-2008).
Mode: Global Config Mode
Privilege Level: Administrator
Format: ptp operation
no ptp operation
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no ptp operation
41.1.2

ptp clock-mode

Configure PTPv2 (IEEE1588-2008) clock mode. \nIf the clock mode is chan-
ged, PTP will be initialized.
Mode: Global Config Mode
Privilege Level: Administrator
Format: ptp clock-mode <P-1>
Parameter Value
v2-boundary-clock
P-1
v2-transparent-clock
41.1.3

ptp sync-lower-bound

Configure the lower bound for the PTP clock synchronization status \n(unit:
nanoseconds). If the absolute value of the offset \nto the master clock is
smaller than the lower bound, \nthe clock's status is set to synchronized
(true).
Mode: Global Config Mode
Privilege Level: Administrator
Format: ptp sync-lower-bound <P-1>
Parameter Value
1..999999999
P-1
246
Meaning
Meaning
41.1 ptp
RM CLI HiOS-2S RSPS