Herunterladen Diese Seite drucken

B. Braun INFUSOMAT-secura Reparaturanleitung Seite 42

Vorschau ausblenden Andere Handbücher für INFUSOMAT-secura:

Werbung

Technical Data
Nominal voltage
220 V — 50/60 Hz (Ord.-No. 871 902/0)
240 V ~ 50/60 Hz (Ord.-No. 871 904/7)
100 V ~ 50/60 Hz (Ord.-No. 871 900/4)
120 V ~ 50/60 Hz (Ord.-No. 871 901/2)
200 V ~ 50/60 Hz (Ord.-No. 871 905/5)
Classification
Protection class
Type
RFI
"oisture protection
Duration of operation
Environmental conditions
a. operation
rel. humidity
temperature
atm. pressure
9. transport and storage
"sl. humidity
:emperature
sim. pressure
Accumulator type
Accumulator capacity
Recharge time
Air detector
technical sensivity
alarm activated
Deviation of preselected
želivery rate (including the
zisposables recommended by
ine manufacturer)
Automatical alarm activated in
case of dosage failure
Occlusion pressure
Delivery range
Preselection of volume
Nurse call
Nominal current
Fuse (5x20 mm acc. to IEC 127)
0.12 A
T0.2
A
0.11 A
102
А
0.26 A
TO4
A
0.22 A
TO.315 A
0.13 A
T0.25
A
according to IEC 601-1 first edition 1977
(identical to DIN IEC 601 Teil 1/VDE 0750 Teil 1/05.82
and BS 5724 part: 1:1979)
|
CF (240 V — Ord.-No. 871904/7: Type: B)
B (according to DIN VDE-0871/6.78 and DIN VDE 0875
part 1/11.84, respectiviy EWG-Directive 82/499 and
CISPR 11)
drip-proof
100% (continous)
30% ... 75%
+10°C...+40°C
700 mbar... 1060 mbar
10% ... 100%
—40°C...+70°C
500 mbar... 1060 mbar
nickel-cadmium 4.0 Ah 8x 1.2 V (rechargeable)
>3.5 h at max. delivery rate
>20h
air bubbles =0.05 ml
air bubbles =0.3 mi
+5%
<+0.5%
<150 kPa (<1.5 bar)
1...999 mi/h (increments of 1 mi/h)
1...9999 ml (increments of 1 mi)
max. 24 V/1 A/24 VA polarity connections
interchangeable
app. 6.8 kp
130 x 270
x 260 (mm)
37

Werbung