6 Causes of faults and remedies

Fault
Position skips
of the measuring
system
Printed in the Federal Republic of Germany
12/09/2019
Cause
Remedy
Vibrations, impacts and shocks, e.g. on
presses, are dampened with "shock modules".
Strong vibrations
If the error recurs despite these measures, the
measuring system must be replaced.
Perhaps isolated flanges made of plastic help
against electrical faults, as well as cables with
Electrical faults
twisted pair wires for data and supply.
EMC
Shielding and wire routing must be performed
according to the construction guidelines.
TR - ELA - BA - DGB - 0022 - 09