10
SPECIFICATIONS
U9C force transducer
Nominal (rated)
force
Accuracy
Accuracy class
Relative reproducibil
ity and repeatability
errors in unchanged
mounting position
Relative reversibility
error
Non-linearity
Relative creep
(30 min)
Bending moment
influence at 10%
Fnom * 10 mm
(typical)
Temperature coefficient of sensitivity
in the nominal (rated)
temperature range
in the operating
temperature range
Temperature coefficient of zero signal
in the nominal (rated)
temperature range
in the operating
temperature range
Rated electrical output
Nominal (rated)
output
Relative zero signal
error
Sensitivity error
Rated output variation
for tension/pressure
58
F
N
50 100 200
nom
kN
b
%
rg
v
%
d
%
lin
d
%
cr,F
d
%
Mb
%/
TC
S
10K
%/
TC
S
10K
%/
TC
0
10K
%/
TC
0
10K
C
mV/V
nom
d
mV/V
s,0
d
%
c
d
%
zd
0.5
< 0.2
0.4
1
2
5
10
0.2
< 0.2
< 0.2
< 0.25
< 0.1
2.3
0.2
< 0.5
< 0.2
< 0.50
1
± 0.2
< 1
< ± 1
SPECIFICATIONS
20
50
2.5 0.47
U9C