Fig. 7.4
Example diagram of installation with knuckle eye
3. Shaft surface quality and hardness
The recommended surface roughness is ≤ 10 μm.
The shaft must have a minimum hardness of 50 HRC.
20
Customer's construction
Customer's shaft holder
Shaft
Recommended play,
see Tab. 7.4, page 19
Threaded connector for mounting
on force transducers
MECHANICAL INSTALLATION
U9C