In the event that the switch should be triggered for a falling force
u
Switch the logic to "Low active"
u
Set the field "SP1" to the higher force (in the logic defined above)
u
If you would like the new switchover for a rising force to occur at a lower force value,
then enter this lower force value in field SP2. If you set the same for both values, the
switch will work without the hysteresis.
Window mode
The range can be monitored in window mode.
S
Enter both of the forces that define the switching points, and SP1 and SP2. The order
is irrelevant.
S
If required, you can enter a hysteresis which will then be identical for the upper and
lower switching point.
S
You can invert the output by selecting "High Active" or "Low Active". If "High Active" is
selected, the output is logical 1 if the value is in the window range.
The state of the limit value switch can be issued via two digital outputs in the form of a
24 V switching signal in the electronics.
Index
Sub­
(hex)
index
(hex)
0x003C 0x00
0x003C 0x01
0x003C 0x02
0x003D 0x00
38
Permissio­
Data
ns
Type
ReadWrite
UIntegerT 1
ReadWrite
Float32T
ReadWrite
Float32T
ReadWrite
UIntegerT 1
Data
Array
Descripti­
Size
Length
on
bytes
8
SSC1_1
Params
(SP1,
SP2)
4
SSC1_1
SP1
4
SSC1_1
SP2
6
SSC1_1
Config
(logic,
mode,
hyst)
Description
Access to all
of the
parameters
for switching
channel 1
Switching
point for
switching
channel 1
Second
switching
point for
switching
channel 2
Access to all
of the config­
urations for
switching
channel 1
ELECTRICAL CONNECTION