Only the measurement values that have not been set to zero and have been filtered on a
frequent basis will be used to evaluate the exceeded nominal (rated) force/operating
force. This means that setting them to zero has no impact on the monitoring functions.
An IO-Link event will always be generated if the parameters explained below, are
exceeded. The master transfers the event to the fieldbus level for further analysis.
You can deactivate some of the alarms (e.g., if you are operating the measurement chain
within the operating force). Alarms, that can be deactivated, are referred to as "Warning"
alarms in the following. Alarms, that you cannot deactivate, are known as an "Error".
"Errors" and "Warnings" remain active for as long as the state is outside the permissible
range (e.g., electronics operating outside the temperature range). The "Errors" and
"Warnings" will disappear as soon as this state changes to indicate that the device is
working in the permissible range again. The messages are only displayed briefly.
Trigger
Temperature
error
Operating above
the permissible
temperature
range of the
inline amplifier
Operating below
the permissible
temperature
range of the
inline amplifier
Parameter error
Nominal (rated)
force exceeded
44
Type of
Note
event
Error
Warning
Warning
Error
Warning
EVENT
Description
ID
16384
0x4000 /><!-- "Temperature
fault" -->0x4000
Temperature fault –
Overload Failure
16912
0x4210 /><!-- "Temperature
overrun" -->0x4210 Device
temperature overrun –
Clear source of heat Out-of-
Specification
16928
0x4220 /><!-- "Temperature
underrun" -->0x4220 Device
temperature underrun –
Insulate DeviceOut-of-
Specification
25376
0x6320 /><!-- "Parameter
error" -->0x6320 Parameter
error – Check data sheet
and valuesFailure
6145
0x1801 type="Warn­
ing">Nominal Limit
Exceeded – Maximum
nominal push force was
overrun