Functions

The following chapters describe special functions of the charging station.
5.1

Load management in the local charging network

Load management in a local charging network allows multiple xChargeIn
charging stations to operate on a common supply. The maximum power al-
lowed by the supply line is divided by the master charging station.
Information
Charging at a slave charging station is only possible if there is a connection
to the master charging station. This prevents overloading of the connection.
5.1.1
Equal allocation mode
If the parallel active charging stations in a local charging network request
more power than the power supply provides (set maximum current), the
available charging current is divided evenly across all charging sessions.
Charging current per charging station = set maximum current per
phase / number of active charging sessions on this phase
If insufficient power is available for an additional charging process in the
charging network (set minimum current is underrun), the new charging
process will be lined up. Every 15 minutes, an active charging session is
paused in sequence, lined up at the back of the line, and the next charging
session in the line continues.
5.1.2
Current limiting
The current limiting for the charging station can be regulated in various
ways.
If a current limit is specified via several different types, then the lowest preset
value is used for the currently valid current limit.
5.2

RFID authorization

Certain device variants are equipped with an RFID reader, which enables
the authorization of a charging process with RFID cards in accordance with
ISO 14443 and ISO 15693. The RFID authorization only allows a charging
Configuration manual V1.04
© EATON
Setting by means of DIP switches locally on each charging station
Specification by master charging station
Specification via UDP connection
Reading out an external meter using Modbus TCP
Functions