Herunterladen Diese Seite drucken

Linking The Robotic Mowers And Master Docking Station; Possible Cause - Viking MI 632 M Gebrauchsanleitung

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
There should be no robotic mower in any
of the other docking stations.
The docking stations must be freely
travellable. Place the robotic mowers of
the free docking stations within the
mowing area.
Then press the OK button on the
control panel.
9.14 Linking the robotic mowers and
master docking station
The robotic mowers can only be
operated if they correctly receive
the wire signal emitted by the
master docking station.
Checking the wire signal may take several
minutes. The red STOP button on top of
the machine terminates the link, the
previous installation assistant step is
called up.
122
Normal reception
Wire signal OK:
The text "Wire signal OK"
appears on the display. The
robotic mower and the master
docking station are correctly linked.
Continue initial installation by
pressing the OK button.
"GPRS" energy mode is activated
following successful linking.
Interrupted reception
The robotic mower receives no
wire signal:
The text "No wire signal"
appears on the display.
The robotic mower receives a
faulty wire signal:
The text "Check wire signal"
appears on the display.
The robotic mower receives a
reversed-polarity wire signal:
The text "Connections swapped
or iMow outside" appears on the
display.

Possible cause:

– Temporary malfunction.
– Robotic mower is not docked.
– Perimeter wire has been connected
incorrectly (reversed polarity).
– Master docking station is switched off or
not connected to mains supply.
– Faulty plug connections.
– Minimum perimeter wire length not
reached.
– A coiled power cable in the vicinity of
the master docking station.
– Excessively long perimeter wire ends.
– Perimeter wire break.
– Extraneous signals such as mobile
phones.
– Live underground cables, reinforced
concrete or disruptive metals in the
ground under the master docking
station.
– Maximum length of the perimeter wire
exceeded. (
12.1)
Remedy:
– Repeat linking without other corrective
action.
– Dock the robotic mower. (
– Connect the perimeter wire ends
correctly. (
9.12)
– Check the master docking station
mains connection, roll out the power
cable in the vicinity of the master
docking station, do not set down coiled.
– Check the perimeter wire plug
connections, cut off excessively long
perimeter wire ends. (
– Install the accessory (AKM 100).
– Check the LED indicator on the master
docking station. (
13.1)
– Repair the wire break.
0478 131 9937 B - EN
15.7)
9.12)

Quicklinks ausblenden:

Werbung

Fehlerbehebung

loading