Herunterladen Diese Seite drucken

Viking MI 632 M Gebrauchsanleitung Seite 110

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Internal docking zone:
During the installation of an internal
docking zone, the master docking
station (A) and all other docking stations
(B) are located directly in the mowing
area (E) (grey area).
To ensure that the machines are properly
docked and undocked, the master docking
station (A) and all other docking
stations (B) must be installed while
maintaining defined distances.
108
The areas around the docking zone and
outside of the perimeter wire must be flat
and freely travellable. Remove any bumps
or depressions.
Minimum distance from the docking station
to the perimeter wire in corners.
C = 1 m
Minimum distance between the docking
stations:
D = 3 m
There must be a free, level area (2) with a
radius of at least 1 m in front of each
docking station (1). Remove any bumps or
depressions.
External docking zone:
During the installation of an external
docking zone (C) (grey area), the master
docking station (A) and all other docking
stations (B) are located outside the
mowing area (E) (grey area).
The external docking zone (C) and the
mowing area (E) are connected by an
installed corridor (D).
The installation of an external
docking zone means that there are
no docking stations directly in the
mowing area and likewise there are
no robotic mowers in this area
outside of the active times.
0478 131 9937 B - EN

Quicklinks ausblenden:

Werbung

Fehlerbehebung

loading