Herunterladen Inhalt Inhalt Diese Seite drucken

Recommissioning After Cleaning Or Maintenance Operations; Decommissioning The Fork Lift Truck; Operations To Be Performed Prior To Decommissioning; Measures To Be Taken During Decommissioning - Jungheinrich EFG 430 Betriebsanleitung

Elektro-fahrersitzgabelstapler
Vorschau ausblenden Andere Handbücher für EFG 430:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6.13

Recommissioning after cleaning or maintenance operations

Recommissioning of the truck following the performance of cleaning or maintenance
work is permitted only after the following operations have been performed:
–– Check the horn for proper functioning.
–– Check the master switch for correct functioning.
–– Check the brake for correct functioning.
–– Lubricate truck according to lubrication schedule.
7

Decommissioning the fork lift truck

If the fork lift truck is to be decommissioned for more than two months, it must be
parked in a frost-free and dry location and all measures to be taken before, during and
following decommissioning must be performed as detailed below.
M
During decommissioning, the fork lift truck must be jacked up, ensuring that the
wheels are clear of the ground. Only this measure will ensure that wheels and wheel
bearings do not suffer damage.
If the fork lift truck is to be decommissioned for more than 6 months, additional meas-
ures must be discussed with the Service Department of the manufacturer.
7.1

Operations to be performed prior to decommissioning

–– Thoroughly clean the fork lift truck.
–– Check the brakes for correct function.
–– Check the hydraulic oil level and top up if required (refer to chapter F).
–– Apply a thin film of oil or grease to all parts not protected by a paint coating.
–– Grease the fork lift truck as detailed in the lubrication chart (refer to chapter F).
–– Recharge the battery (refer to chapter D).
–– Disconnect and clean the battery. Apply pole grease to the battery poles.
Z
In addition to this, all instructions given by the battery supplier must be observed.
–– Spray all exposed electrical contacts with a suitable contact spray.
7.2

Measures to be taken during decommissioning

Every 2 months:
–– Recharge the battery (refer to chapter D).
M
Battery-operated fork lift trucks:
Regular recharging of the battery is very important; otherwise, exhaustive depletion
of the battery caused by self-discharging would occur. Owing to sulfatisation, this will
result in the destruction of the battery.