› Step 2: Calculate the offsets with a resolution of 0.1 mm
‒ Print the G-code step2_0.6_XY_calibration.gcode which has a
resolution of 0.1 mm.
‒ When the print is finished, wait until the bed is cold and release the part off
the bed.
‒ Identify the offsets. The shapes printed with extruders T0 and T1 should
match just in one point. Identify the point in which they match and write
down the offset using the template below.
Fig. 7-6: Template – on this example: X offset = 0,3 mm, Y offset = +0,1 mm
‒ Go to the Advanced Menu, update the offsets (add the new values to the
previous ones) and save.
Fig. 7-7: Offset adjustment