8 Installing the Perimeter Wire
General requirements
a
4
► Make sure that the following conditions are ful‐
filled:
– The minimum distance between the wire
loops (4) must be at least a = 74 cm (length:
®
2x iMOW
Ruler).
– The distance between the perimeter wires
(2) must be at least b = 55 cm.
– The distance to side obstacles must be at
least c = 15 cm.
A
d
3
90°
► Make sure that the following conditions are ful‐
filled:
– The guide wire (3) can be routed before the
corridor for a length of at least d = 37 cm
(length: 1x iMOW
and at a right angle (90°) to the corridor.
– The guide wire (3) can be routed after the
corridor for a length of at least e = 2 m in a
straight line and at a right angle (90°) from
the corridor into the mowing area (B).
► If the distances and lengths cannot be com‐
plied with, the mowing area (B) must be sepa‐
rated from the main mowing area (A) and a
side area must be installed.
0458-011-9801-A
c
2
b
4
2
c
B
e
90°
®
ruler) in a straight line
Installing a corridor
2
A
a
A
► Guide the perimeter wire (2), as illustrated,
from the main mowing area (A) to the mowing
area (B).
► If the corridor is to be installed in an arc: Route
the perimeter wire (2) for a length of a = 74 cm
(length: 2x iMOW® ruler) at the start and end
of the corridor and at a right angle (90°) to the
mowing area.
► Route the perimeter wire (2) clockwise around
the mowing area (B) and back to the corridor.
a
► Route the perimeter wire (2) parallel and
closely together for 37 cm (length: 1x iMOW
ruler) without the perimeter wires crossing
over each other.
► Route the perimeter wire (2) parallel at a dis‐
tance of at least 55 cm toward the main mow‐
ing area (A).
English
B
a
2
4
2
a
B
2
2
®
75