Description
4000
Power stage configuration:
1 = power stage on;
0 = power stage off;
4002
Resets current alarm and
warning messages
4007
Specifies the slave that will
be addressed (0 = broad-
cast / same values for all
slaves)
4008
Alarm policy for modules:
0 = strict (system switches
to alarm state if at least
one module is in alarm
state)
1 = relaxed (system swit-
ches to alarm state if all
modules are in alarm state)
4010
Specifies the sub slave that
will be addressed (0 =
broadcast / same values
for all sub slaves)
4011
Use the modbus slave ID
for addressing
4100
Maximum battery voltage
(charge current will get limi-
ted)
4101
Minimum battery voltage
(discharge current will get
limited)
4102
Maximum battery voltage
(charge current will get limi-
ted)
4103
Minimum battery voltage
(discharge current will get
limited)
4106
Maximum battery current
during charging
4109
Maximum battery current
during discharging
4112
Maximum voltage of vol-
tage current characteristic
4115
Maximum current of voltage
current characteristic
4118
Start current of voltage cur-
rent characteristic
4121
Maximum power at DC-ter-
minal
4124
Maximum battery voltage
alarm threshold for DC-ter-
minal (power stage shut-
down)
70
Bedienung
Unit
Res
Defa
Min
olu-
ult
tion
-
1.0
0
0
-
1.0
0
0
-
1.0
0
0
-
1.0
1
-
1.0
0
0
-
1.0
0
0
V
0.01
4800
0
V
0.01
0
0
V
0.1
480
0
V
0.1
0
0
A
0.1
1670
0
A
0.1
1670
0
V
0.1
100
100
A
1.0
50
5
A
1.0
5
1
W
1.0
9000
0
V
0.1
750
0
Max
Data
Typ
Len
type
e
gth
1
UIN-
Coil
1
T16
1
UIN-
Coil
1
T16
16
UIN-
Reg
1
T16
ister
UIN-
Reg
1
T16
ister
16
UIN-
Reg
1
T16
ister
1
UIN-
Coil
1
T16
7500
UIN-
Reg
1
T16
ister
7000
UIN-
Reg
1
T16
ister
750
UIN-
Reg
1
T16
ister
700
UIN-
Reg
1
T16
ister
2500
UIN-
Reg
1
T16
ister
2500
UIN-
Reg
1
T16
ister
700
UIN-
Reg
1
T16
ister
167
UIN-
Reg
1
T16
ister
50
UIN-
Reg
1
T16
ister
12000
UIN-
Reg
1
T16
ister
780
UIN-
Reg
1
T16
ister
2024-08-01
A67-0140-00.BKde-0
FCr
FCw
01
05
01
05
03
06
03
06
03
06
01
05
03
06
03
06
03
06
03
06
03
06
03
06
03
06
03
06
03
06
03
06
03
06