Number
Message
10018
Set value is out of
range
11025
High module tempe-
rature. Power dera-
ting active. Check
cooling conditions
to prevent shut-
down.
11026
High ambient air
temperature detec-
ted. Power derating
active.
Warnmeldungen DC-DC
A67-0140-00.BKde-0
01-09
Effect
Set value is ignored.
Power reduction
dependent on semi-
conductor tempera-
ture.
Power reduction
dependent on ambi-
ent temperature.
2024-08-01
Cause
Action
Set value is out of
Make sure set
range.
value is inside of
allowed range.
Semiconductor tem-
Check cooling con-
perature too high.
ditions and airflow.
Ambient air tempe-
Check cooling con-
rature too high.
ditions and ambient
temperature.
Caused
by
System
control
DC-DC
module
DC-DC
module
Tab. 33
103
Fehlersuche