Technical data
Pump code group I
"Operating part" [EcoUp|E|S]
Item 1: 'Pump name / electrical version'
Buttons/settings: On/Off, Mode, Test, Viscosity high/low, 1:100
EcoUp
LEDs: Mode, operating status / metering mode, alarm
Inputs/outputs: Release signal, level input put level warning and empty signal, alarm/level output
Item 2: 'Mains power supply'
E
2.5 m power cable with Euro plug
U
2.5 m power cable with US plug
N
2.5 m power cable without power plug (wire sleeves)
Item 3: 'Control unit version'
S
Standard
T
Rotated control unit
Pump code group II
"Pump head" [01110S|D|F|C|0|0|S]
Item 4: 'Litre capacity/back-pressure/driver unit'
Code:
00510X
01110S
01110S
03003S
Item 5: 'Material: Pump head/valves'
Code:
D
P
D
Item 6: 'Material: Seals'
Code:
F
F
E
T
K
Item 7: 'Material: Valve balls'
Code:
C
C
T
S
Item 8: 'Valve spring'
Code:
0
0
1
2
3
Item 9: 'Hydraulic connection'
Code:
0
0
MAN049656 Rev. 3-01.2024
Capacity in litres:
Pressure [MPa
[l/h]
(bar)]
0,05 - 5
1 (10)
0,11 - 11
1 (10)
0,3 - 30
0,3 (3)
Description:
PP (polypropylene)
PVDF (polyvinylidene difluoride)
Description:
FKM (fluorocarbon rubber)
EPDM (ethylene propylene diene monomer rubber)
PTFE coated (polytetrafluoroethylene)
FFPM (Kalrez) (perfluorinated rubber)
Description:
Ceramic
PTFE (polytetrafluoroethylene)
Stainless steel V4A
Description:
No spring
SAV: 0.1 bar, DRV: 0.1 bar
SAV: no spring, DRV: 0.3 bar
SAV: no spring, DRV: 0.5 bar
Description:
Without hose connection parts
82
Size of driver unit
XS
S
S