Terminal assignment
The terminals can be accessed after removing the terminal cover ( Fig. 11 ,
NOTICE!
Only skilled personnel are authorised to carry out any changes to the terminal
assignment. Contact our Customer Service if you have any queries or need
assistance
Ä Chapter 1.8 'Contact' on page 11 .
Fig. 12: Terminal assignment for 'EcoUp'
L1 Mains phase (live conductor)
N
Neutral (earth)
1
Alarm output: Common
2
Alarm output: NO
3
Metering volume output: -
4
Metering volume output: +
5
Pulse input: GND
6
Pulse input: Pulse signal
Permissible external cable
AD Ø = 5.1-5.7 mm. LIYY 4x0.5; LIYY 5x0.34; LYCY 2x0.34
Permissible cables: Oilflex 4x0.5
IP65 is applicable only when the specified cable is being used.
Assembly and connection
7
Output: 5 Volt
8
Enable input: GND
9
Enable input: enable signal
10 Level input: GND
11
Level input: Level pre-warning
12 Level input: Empty signal
connection)