12.1
Conversion
Turning the control unit
To allow the pump to be adjusted to the site conditions, it is possible to turn the grey
control unit (operating unit / upper part of the pump).
DANGER!
Risk of electric shock
Be sure to disconnect the power supply immediately and to secure against
accidental switch-on!
1
Fig. 31: Turning the control unit
1.
Loosen the screws on the control unit
2.
Lift the control unit up and remove
3.
Turn the control unit in the desired direction and place it on the housing
4.
Tighten the fixing screws on the control unit (operating unit / upper part of the pump)
.
2
The screws are not secured against falling out!
Make sure they are not lost.
Use only original screws.
Two cables that pass control signals to the pump are located between the
pump control Control unit and the bottom part of the pump.
Ensure that these do not become trapped during the changeover.
The blue pump housing contains a seal for the control unit. During
assembly, ensure that the seal is free of contamination to prevent leaks.
The tightening torques for the screws on the control unit . 1 Nm. To
prevent damage to the thread, we recommend tightening the screws by
hand.
3
.
.
75
Modification/upgrade
4
.
MAN049656 Rev. 3-01.2024