Herunterladen Diese Seite drucken

ECOLAB EcoUp Betriebsanleitung Seite 155

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
9.2
LED error messages
The 'EcoUp' diaphragm metering pump has a red alarm LED that either
flashes (in case of level warning) or lights up (in case of empty signal or a
fault).
If the alarm LED is lit, please first check your metering container to see if the fill
level is still above the empty detection level. If the alarm was not caused by an
empty signal from the container, there is a fault with the pump.
Display
Fault
Motor control has
overheated
Dosing mode - sensor
not reached
Red alarm LED is on
Suction mode - sensor
not reached
No feedback from gear
box when switching on
If the fault is still present after all checks have been completed, please send
the pump to the Customer Service team.
Ecolab Engineering GmbH' on page 9
Resetting error messages
1.
[Press the ON/OFF] button
Operational faults and troubleshooting
Effect
Cause
Back-pressure too
high, bottlenecks in the
Pump is stopped
metering line, metering
line blocked, motor
driver defective
Back-pressure too
high, bottlenecks in the
Pump is stopped
metering line, metering
line blocked
Suction pressure too
high, bottlenecks in the
Pump is stopped
suction line, blocked
suction line
Contact problem with
feedback cable
Pump is stopped
Feedback PCB faulty
Ä Chapter 1.5 'Repairs/returns to
for approx. 1 second.
57
Action
Reduce and retest
pump performance
on a trial basis,
check back-pressure,
check the dosing line
for pressure-increasing
bottlenecks, use a pipe
with a larger cross-
section if necessary,
change the motor
board.
Reduce and retest
pump performance
on a trial basis,
check back-pressure,
check the dosing line
for pressure-increasing
bottlenecks, use a pipe
with a larger cross-
section if necessary.
Reduce and retest
pump performance on
a trial basis, check
the dosing the suction
for pressure-increasing
bottlenecks, use a pipe
with a larger cross-
section if necessary.
Check the feedback
cable connection
Replace the feedback
PCB