Oil heater K 120 (R) / K 160 (R)
20.2.3
Setting the burner
NOTICE
Observe the applicable operating manual of the
burner manufacturer as well as all information on
the burner from the tableMalfunctions during op-
eration
[
66].
Fig. 28:
Burner settings
1 Burner head adjus-
ting screw
3 Connection for
pressure gauge
Adjust the burner head
Check the burner head setting regularly. If neces-
sary, the burner head can be readjusted using the
adjusting screw.
Adjust the combustion air
a) Loosen the lock nut on the combustion air ad-
justing screw.
74 / 85
2 Combustion air set
screw
4 Pump pressure ad-
justing screw
b) Adjust the combustion air at the adjusting
screw from below using a screwdriver.
c) Perform a Exhaust gas analysis
 You have now adjusted the combustion air.
Set pump pressure
a) Screw the pressure gauge (article no.
4000005) to the connection.
b) Use a screwdriver to adjust the pressure on
the pump pressure adjustment screw.
NOTICE! Turning to the right increases the
pressure, turning to the left decreases the
pressure.
c) Perform a Exhaust gas analysis
 You have set the pump pressure.
See also
 Maintenance schedule
20.2.4
Exhaust gas analysis
a) Drill a hole at a height of 400 mm with a di-
ameter of 8 mm into the exhaust gas duct.
Fig. 29:
Installed device for exhaust gas analysis
1 Connection point in
the exhaust gas
duct
b) Connect the exhaust gas analysis measuring
device (part no. 4000040) to the device.
[
74].
[
74].
[
76]
2 Measuring device
for exhaust gas
analysis
EN