Oil heater K 120 (R) / K 160 (R)
16.2
Transport by crane
WARNING
Danger of raised loads falling down
The sudden lowering or falling of loads that have
been lifted is life-threatening.
a) Do not remain under raised loads!
b) Pay attention to the information on the
transport packaging, where the means of
transport are described!
Follow these instructionsto safely transport the
machine/machine component with the crane .
a) Use trusses to transport the machine without
the danger of any possible warping.
b) Only use the fixing eyelets to keep the ma-
chine/machine components in a vertical posi-
tion when it is being transported by crane.
c) Always use all transport eye bolts. Always dis-
tribute the load over all the transport eye
bolts provided, never lift the device using only
one transport eye bolt.
d) Only lift the machine vertically.
16.3
Assembly and connection
WARNING
Risk of injury due to improper connection
The operation of mobile oil-heated hot air heaters
can result in hazards due to oil leakage or faulty
exhaust gas routing.
a) Only qualified and trained personnel may
connect the device, install the exhaust gas
duct and establish the oil supply.
60 / 85
CAUTION
Risk of injury due to the device tipping
over or rolling away.
If the device is not erected stably, it may roll or tip
over.
a) Prevent the device from rolling away or tip-
ping over by placing it on a flat surface.
b) Place the device on its skids or brake the
lockable wheels.
CAUTION
Risk of being crushed during installation of
hoses and chimney
You may injure your hands when installing the oil
supply and exhaust gas duct.
a) Wear protective gloves.
Attention
Destruction and sooting of the heat ex-
changer
Incorrect installation of the exhaust gas duct can
lead to destruction of the heat exchanger.
a) Install an additional condensate trap for an
extended exhaust gas duct.
b) Install the exhaust gas duct in such a way
that no back pressure can occur in the ex-
haust gas duct at any time.
NOTICE
Use suitable extension cables
Consider the voltage drop when using extension
cables. This should never exceed 3%.