Oil heater K 120 (R) / K 160 (R)
– and by observing all instructions given in the
chapter Safety
[
48].
Assembly, scope of delivery and
accessories
Fig. 17:
K 120 Exterior view
1 Exhaust pipe nozzle
3 Operating panel
5 Air inlet
7 Stand or wheels
(type R)
9 Air outlet
11 Inspection window
The scope of supply includes:
– Air heater
– one strand oil pipe including foot valve and
quick coupling connection
– Handlebar
– Operating manual burner
– Operating manual
The following are available as accessories:
– A console with which several devices can be
stacked on top of each other. Further acces-
sories, see Accessories
How it functions
During operation, the heating oil is sucked in by
the burner pump via the suction line from the tank
54 / 85
2 Transport eyebolts
4 Handlebar
6 Wheel
8 Transport straps for
forklift trucks
10 Oil pipe connection
12 Burner box
[
83].
provided or from a permanently installed oil sup-
ply. The oil quantity required for the heat output is
fed to the burner nozzle via the pressure line,
sprayed into the combustion chamber and ignited
there. The result is a flame which, together with
its combustion gases, heats the combustion
chamber and the heat exchanger. Excess heating
oil pumped by the burner pump is returned to the
burner pump.
The single-stage integrated system component
burner (ISK burner) starts automatically as soon
as a heat demand is present.
After a short preheating period, the temperature
control switches on the warm air fan. The fan
blows the cold air sucked in through the combus-
tion chamber and the heat exchanger. This warms
the air. The heated air exits on the opposite side
through the blow-out nozzle.
The combustion exhaust gases are discharged via
the exhaust gas duct. After switching off, the fan
continues to run until the heat exchanger has
cooled down.
NOTICE
Exhaust gas routing
The exhaust gas can be routed by the operator.
The exhaust pipe used must be at least one me-
tre long and protected with a rain hood. We rec-
ommend the use of HEYLO original accessories
and spare parts (see Supplementary documents
[
79]).
Operation with room thermostats
When a room thermostat is connected, it indirectly
controls the burner and ensures constant temper-
atures in the room to be heated. If the device is
operated unobserved in closed rooms, a room
thermostat must be used.
See also
 Intended use
[
55]