NOTICE
Fireplace testing during operation in Ger-
many
Fireplaces that are operated for longer than 3
months after commissioning must be inspected
by the chimney sweep in accordance with the
BImSchV.
a) Mount the handlebar to the device using a
Phillips screwdriver and the enclosed screws.
b) Position the device at the place of installation
with the help of the handlebar.
c) Insert the mains plug into a suitable electrical
outlet equipped with an RC circuit-breaker.
For 400 V devices, pay attention to the indi-
cated direction of rotation of the fan.
Installing the exhaust gas duct
a) For outdoor installation, place an original
HEYLO exhaust pipe (see Accessories
on the intended nozzle on the roof of the de-
vice.
b) To protect against rain or snow, install a rain
hood. Make sure that this does not reduce the
diameter of the exhaust pipe nozzle and the
exhaust pipe.
c) When connecting to a permanently installed
chimney, consult a chimney sweep. The mi-
nimum draft must be 0 PA.
d) If you extend the exhaust gas duct, install an
additional condensate trap in which the con-
densate produced is collected. The resulting
condensate can otherwise destroy the heat
exchanger.
EN
Installing the fuel tank
NOTICE
The heating oil supply is the responsibility
of the operating company
The supply of the device with heating oil is not
part of the delivery of the appliance and is the
responsibility of the operating company.
The connection between heater and tank may
only be established with original HEYLO compo-
nents or in accordance with the regulations of
technical regulation TRGS 509.
The tank must be protected against moisture
penetration. In outdoor installations, the tank
must be approved for this purpose.
HEYLO recommends winter heating oil or heating
oil with flow improvers.
a) Make sure that the oil tank has a safety dis-
[
83])
tance of at least 60 cm from the heater.
b) Plug the quick coupling connection of the
supplied oil supply line onto the hydraulic
connection on the device. Make sure that the
connection coupling is seated correctly!
c) If the device is positioned lower than the tank,
an anti-snub valve must be installed in the oil
pipe.
d) Check the cleanliness of the tank and ensure
regular cleaning to avoid malfunctions during
operation.