Herunterladen Diese Seite drucken

Scheppach HBS30 Original Bedienungsanleitung Seite 37

Vorschau ausblenden Andere Handbücher für HBS30:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
• Important: Long workpieces must be secured
against tipping at the end of the cutting process (e.g.
with reel-off stand, etc.)
10.2 Performing angled cuts (Fig. 20)
• Set saw bench to desired angle (see 9.3).
• Perform the cut as described under 10.1.
When producing angled cuts, only use the parallel stop
to the right of the saw band.
10.3 Freehand cuts (Fig. 21)
• One of the most important features of a band saw is
the ease with which it can cut curves and radii.
• Lower the saw band guide (5) onto the workpiece
(see 8.9).
• Switch on the saw.
• Press the workpiece firmly onto the saw bench (7)
and slowly slide into the Bandsaw blade (26).
• In many cases it is helpful to roughly saw curves and
corners approximately 6 mm from the line.
• If it is necessary to saw curves that are too tight for
the saw band used, auxiliary cuts must be sawn up
to the front face of the curve, so that these fall off as
wood waste when the final radius is sawn.
10.4 Executing cuts with the transverse cutting
gauge (Fig. 22 + Fig. 23)
• Set transverse cutting gauge (25) to the desired an-
gle (see 8.16)
• Perform the cut as described under 10.1.
11. Electrical connection
The electrical motor installed is connected and ready
for operation. The connection complies with the appli-
cable VDE and DIN provisions.
The customer's mains connection as well as the ex-
tension cable used must also comply with these reg-
ulations.
Important information
In the event of an overloading the motor will switch it-
self off. After a cool-down period (time varies) the mo-
tor can be switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the wall
outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with the marking „H05VV-F".
The printing of the type designation on the connection
cable is mandatory.
AC motor
• The mains voltage must be 220 - 240 V~ 50 Hz.
• Extension cables up to 25 m long must have a
cross-section of 1.5 mm
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Machine data - type plate
12. Cleaning, maintenance and storage
m IMPORTANT!
Prior to any adjustment, maintenance or service work
disconnect the mains power plug!
Cleaning
Keep all safety devices, air vents and the motor hous-
ing free of dirt and dust as far as possible. Wipe the
equipment with a clean cloth or blow it with com-
pressed air at low pressure.
We recommend that you clean the device immediately
each time you have finished using it.
Maintenance
There are no parts inside the equipment which require
additional maintenance.
www.scheppach.com
.