4.2

Strain gage full or half bridge and piezo-resistive sensors in 6-wire

configuration with Zero-Wire TEDS, version for D-sub-HD15
Measurement signal *
Measurement signal +
Sense lead *
Bridge excitation voltage *
Sense lead +
Bridge excitation voltage +
Fig. 2.2
Module wiring with a full bridge; with a half bridge, connection 4 is omitted
u
Solder the module between the first and second rows of the plug to pins 1 to 5
(Fig. 2.3 and Fig. 2.4).
5
10
15
Fig. 2.3
Mounting the TEDS module in the plug
u
Then turn the plug around and solder connections 6 to 10 on the other side (Fig. 2.3
and Fig. 2.5).
8
Zero-wire TEDS
Cable wire colors (HBM transducer):
bl = blue; gn = green; gy = gray;
rd = red; bk = black; wh = white;
1
6
rd
wh
2
bk
gr
1
bl
gn
3
INSTALLATION AND CONNECTION
4
TEDS