Herunterladen Inhalt Inhalt Diese Seite drucken

HBM TEDS Montageanleitung Seite 28

Vorschau ausblenden Andere Handbücher für TEDS:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Parameter
Minimum Electrical
Value
Maximum Electrical
Value
Mapping Method
Discrete Signal Type
Discrete Signal
Amplitude
Discrete Signal
Configuration
Transducer Response
Time
Excitation Level
(Nominal)
Excitation Level
(Minimum)
Excitation Level
(Maximum)
Excitation Voltage
Type
26
1)
Value
Unit
0.0
Hz
60000.0
Hz
Linear
Bipolar
4
V
Single
1.00000
s
00u
0.1
V
0.1
V
0.1
V
DC
Requires
Explanation
rights at
level
CAL
The difference between
these values is the
sensitivity (frequency at
maximum speed) according
CAL
to the data sheet or test
record, or from the
calibration.
This entry cannot be
changed.
Possible settings: Contact to
Ground,
Contact to Power,
Active Low,
Active High,
Bipolar.
Input amplitude of the
sensor signal
Signal evaluation:
Single or with F2 signal
(double 90 degree), with or
without zero index signal,
etc.
Irrelevant to HBM
transducers.
ID
Nominal (rated) voltage.
ID
Lower limit for the operating
range of the excitation volt­
age according to data sheet.
ID
Upper limit for the operating
range of the excitation volt­
age according to data sheet.
ID
Possible settings:
DC,
Bipolar DC,
AC (rms)
TEDS
TEDS TEMPLATES

Werbung

Inhaltsverzeichnis
loading