Herunterladen Inhalt Inhalt Diese Seite drucken

HBM TEDS Montageanleitung Seite 27

Vorschau ausblenden Andere Handbücher für TEDS:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Parameter
Calibration Period
(Days)
Measurement
Location ID
1)
As an example, the values show an HBM displacement transducer of type WA, measuring range 50
mm.
HBM template: Frequency/Pulse Sensor
Along with the physical and electrical unit, this template defines the display resolution to
be used: 24 bits, 16 bits or 8 bits (SINGLE Precision). You also have to choose, for exam­
ple, between the variants "Frequency" or "Counter". For example, a sensor that emits
pulses during one revolution can be defined either as an angle of rotation sensor (count­
ing pulses) or as a speed sensor (measuring frequency).
Parameter
Transducer Electrical
Signal Type
Minimum Velocity
Maximum Velocity
Pulse Measurement
Type
TEDS
TEDS TEMPLATES
1)
Value
Unit
730
days
0
1)
Value
Unit
Pulse
Sensor
0.000
rpm
E+000
1.000
rpm
E+004
Frequen­
cy
Requires
Explanation
rights at
level
CAL
Time before recalibration
USR
Identification number for the
measuring point. Can be
assigned according to the
application.
Possible values: a number
from 0 to 2047. If this is not
enough, you can also use
the HBM Channel Comment
template.
Requires
Explanation
rights at
level
ID
This entry can no longer be
changed after the template
has been created.
CAL
The difference between
these values is the maxi­
mum rotational speed
CAL
according to the data sheet.
CAL
This entry can no longer be
changed after the template
has been created.
25

Werbung

Inhaltsverzeichnis
loading