Lenze 8200 motec Montageanleitung Seite 137

0.55 kw ... 2.2 kw
Vorschau ausblenden Andere Handbücher für 8200 motec:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1)
Keypad
PC
54
OH4
203
OH51
-
OU
22
OUE
75
Pr
72
Pr1
73
Pr2
77
Pr3
78
Pr4
79
Pr5
81
Pt5
L
Fault detection and elimination
Fault
Cause
C0119
1 or 4)
No PTC connected
Controller
Controller too hot inside
overtemperature
PTC monitoring
Motor too hot due to
impermissibly high currents or
(Display when
frequent and too long
C0119 = 2 or 5)
acceleration processes
No PTC connected
DC bus
Mains voltage too high
overvoltage
(Message or TRIP
Braking operation
configurable in
C0310)
Earth leakage on the motor
side
Faulty parameter
All parameter sets are
transmission
defective
when using the
keypad
Faulty PAR1
Parameter set 1 is defective
transfer with
keypad
Faulty PAR2
Parameter set 2 is defective
transfer with
keypad
Faulty PAR3
Parameter set 3 is defective
transfer with
keypad
Faulty PAR4
Parameter set 4 is defective
transfer with
keypad
Internal fault
EEPROM is defective
Time error during
Data flow from keypad or PC
parameter set
interrupted, e.g. because
transfer
keypad was disconnected
during transfer
EDK82MV222 DE/EN/FR 9.0
Fault messages
Remedy
Connect PTC or switch off
monitoring
Reduce controller load
Improve cooling
Check fan in the controller
Check drive dimensioning
Connect PTC or switch off
monitoring
Check supply voltage
Increase deceleration times
When operating with an
external brake resistor:
– Check dimensioning,
connection and supply cable
of the brake resistor
– Increase deceleration times
Check motor supply cable and
motor for earth fault (disconnect
motor from the inverter)
Before enabling the controller,
repeat the data transfer or load
the Lenze setting
Contact Lenze
Before enabling the controller,
repeat the data transfer or load
the Lenze setting.
U
NPT