Herunterladen Inhalt Inhalt Diese Seite drucken

Lenze 8200 motec Montageanleitung Seite 127

0.55 kw ... 2.2 kw
Vorschau ausblenden Andere Handbücher für 8200 motec:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Code
No.
Name
C0034*
Setpoint
selection
range
Standard–I/O
uSEr
(X3/8)
-12-
C0034*
Setpoint
selection
range
(A)
Application I/O
uSEr
1 X3/1U, X3/1I
2 X3/2U, X3/2I
C0037
JOG1
C0038
JOG2
C0039
JOG3
C0050*
Output
frequency
uSEr
(MCTRL1-NOU
T)
C0087
Rated motor
speed
L
The most important codes for commissioning
Possible settings
Lenze
Selection
0
0
Unipolar voltage 0 ... 5 V / 0 ... 10
V
Current 0 ... 20 mA
1
Current 4 ... 20 mA
2
Bipolar voltage -10 V ... +10 V
3
Current 4 ... 20 mA open-circuit
monitored
0
0
Unipolar voltage 0 ... 5 V / 0 ... 10
V
1
Bipolar voltage -10 V ... +10 V
2
Current 0 ... 20 mA
3
Current 4 ... 20 mA
4
Current 4 ... 20 mA open-circuit
monitored
20.00 -650.00
30.00 -650.00
40.00 -650.00
-650.00
300
EDK82MV222 DE/EN/FR 9.0
Commissioning
650.00 JOG = fixed setpoint
{0.02
Hz}
{0.02
650.00
Hz}
{0.02
650.00
Hz}
{Hz}
650.00 Only display: Output
{1 rpm}
16000
T
IMPORTANT
Observe the switch position
of the function module!
Changing the direction of
rotation is only possible with
a digital signal.
Minimum output
frequency (C0010) not
effective
Individual adjustment of
offset and gain
TRIP Sd5, if I < 4 mA
Changing the direction of
rotation is only possible with
a digital signal.
Observe the jumper setting of
the function module!
Minimum output frequency
(C0010) not effective
Changing the direction of
rotation is only possible with
a digital signal.
Changing the direction of
rotation is only possible with
a digital signal.
TRIP Sd5 if I < 4 mA
Additional fixed setpoints
C0440
frequency without slip
compensation
Depending on the controller
NOT