Herunterladen Inhalt Inhalt Diese Seite drucken

Lenze 8200 motec Montageanleitung Seite 135

0.55 kw ... 2.2 kw
Vorschau ausblenden Andere Handbücher für 8200 motec:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1)
Keypad
PC
67
ce6
68
ce7
91
EEr
-
ErP0
...
ErP19
95
FAn1
-
FAn1
105
H05
140
id1
32
LP1
182
LP1
-
LU
L
Fault detection and elimination
Fault
Cause
System bus (CAN)
CAN controller signals
function module
"Warning" or "BUS-OFF"
on FIF has the
status
"Warning" or
"BUS-OFF" status
(configurable in
C0126)
Communication
Node does not respond or is
error in case of
not available
remote
parameterisation
via the system
bus (C0370)
(configurable in
When operating with
C0126)
Application I/O:
Parameter set change-over
has been parameterised
incorrectly
External fault
A digital signal assigned to the
(TRIP-SET)
TRIP-set function is activated
Communication
Various
abort between
keypad and
standard device
Fan failure
Fan is defective
(only 8200 motec
3 ... 7.5 kW)
TRIP or warning
Fan is not connected
configurable in
C0608
Internal fault
Faulty parameter
Motor is not connected
identification
Error in motor
Failure of one/several
phase
motor phases
(Display when
Motor current too low
C0597 = 1)
Error in motor
phase
(Display when
C0597 = 2)
DC bus
Mains voltage too low
undervoltage
Voltage in DC-bus connection
too low
EDK82MV222 DE/EN/FR 9.0
Fault messages
Remedy
Check whether bus termination
is available
Check shielding of the cables
Check PE connection
Check bus load, reduce the
baud rate, if necessary
Check whether bus termination
is available
Check shielding of the cables
Check PE connection
Check bus load, reduce the
baud rate, if necessary
In all parameter sets, the "change
over parameter set" signal
(C0410/13, C0410/14) must be
connected with the same source
Check external encoder
Contact Lenze
Replace fan
Connect fan
Check wiring
Contact Lenze
Connect motor
Check motor supply cables
Check U
boost,
min
Connect motor with a
corresponding power or adapt
motor with C0599
Check mains voltage
Check power supply module
U
NPR