T
Commissioning
The most important codes for commissioning
Code
No.
Name
C0002*
Saving of own
settings
uSEr
(cont.)
C0002*
Loading/copyi
ng of your
own basic
uSEr
settings
(cont.)
C0003*
Non-volatile
parameter
saving
NOO
Possible settings
Lenze
Selection
9
PAR1
5
Own settings
6
Own settings
7
Own settings
8
Own settings
1
0
Parameter not saved in EEPROM
1
Parameter always saved in
EEPROM
3
Own settings saved in EEPROM
EDK82MV222 DE/EN/FR 9.0
Own settings
PAR1
PAR2
PAR3
PAR4
IMPORTANT
You can save your own basic
settings for a controller (e.g.
machine delivery status):
1. Ensure that parameter set
1 is active
2. Controller inhibit
3. Set C0003 = 3,
acknowledge with 
4. Set C0002 = 9,
acknowledge with , to
save your own basic
settings
5. Set C0003 = 1,
acknowledge with 
6. Enable the controller.
Using this function, PAR1 can
be copied to parameter sets
PAR2 ... PAR4
Restorage of own basic
setting in the selected
parameter set
Data loss after mains
disconnection
Active after every mains
connection
Cyclic parameter changes
via bus module are not
allowed.
Subsequently save parameter
set 1 as own basic setting
with C0002 = 9
L