`çåÇáíáçåë Ñçê íêçìÄäÉJÑêÉÉ çéÉê~íáçåW
bñÅÉéí Ñçê íÜÉ ã~áåë Å~ÄäÉI ìëÉ ëÜáÉäÇÉÇ Å~ÄäÉë çåäóK
qÜÉ ëÜáÉäÇ ãìëí ÄÉ Å~êÉÑìääó ÅçååÉÅíÉÇ íç mbK
`çååÉÅí ãçíçê ~åÇ ã~áåë mb ÅçåÇìÅíçêë íç ëÉé~ê~íÉ mb íÉêãáå~äëK
^
_
`
Mains cable L1, L2, L3, PE
PE connection - mains cable
Shielded control cable
Shield connection for control cable (screw shield to shield sheet)
Function module
Isolated terminal (e. g. star point for motor star connection)
X1
Terminal strip - mains connection
PES
HF shield connection by connecting the shield with a surface as large as possible to PE
L
motec with motor or geared motor

Wiring according to EMC requirements

uN
a
EDK82MV222 DE/EN/FR 9.0
Shield connection
1. Prepare cable
2. Route the cable
c
b
3. Tighten the screw.
8200mot101
P
through the eyebolt
of the shield and
bend the eyebolt.
The shield must be
tightly connected to
the shield sheet.
0.7 Nm
6 lb-in
PES
UV