Fault detection and elimination
Fault messages
c~ìäí ãÉëë~ÖÉë çå íÜÉ âÉóé~Ç çê áå íÜÉ é~ê~ãÉíÉê ëÉííáåÖ éêçÖê~ã
däçÄ~ä aêáîÉ `çåíêçä
1)
Keypad
PC
0
noer
71
ccr
61
ce0
62
ce1
63
ce2
64
ce3
65
ce4
66
ce5
NPQ
Fault
Cause
No fault
-
System failure
Strong interference injections
on the control cables
Earth loops in the wiring
Communication
Faulty transmission of control
error on AIF
commands via AIF
(configurable in
C0126)
Communication
CAN-IN1 object receives faulty
error on CAN-IN1
data or communication is
with sync control
interrupted
Communication
CAN-IN2 object receives faulty
error on CAN-IN2
data or communication is
interrupted
Communication
CAN-IN1 object receives faulty
error on CAN-IN1
data or communication is
in case of event
interrupted
or time control
BUS-OFF
Controller has received to
many faulty telegrams via the
(many
system bus and has been
communication
disconnected from the bus
errors occurred)
CAN time-out
In case of remote
parameterisation via the
(configurable in
system bus (C0370):
C0126)
Slave does not respond.
Communication monitoring
time has been exceeded
When operating with
Application I/O:
Parameter set change-over
has been parameterised
incorrectly
When operating with module
on FIF:
Internal error
EDK82MV222 DE/EN/FR 9.0
Remedy
-
Shield control cable
Insert the communication module
properly into the diagnosis
terminal
Check plug connection of bus
module
FIF
Check sender
Increase monitoring time in
C0357/1, if necessary
Check plug connection of bus
module
FIF
Check sender
Increase monitoring time in
C0357/2, if necessary
Check plug connection of bus
module
FIF
Check sender
Increase monitoring time in
C0357/3, if necessary
Check whether bus termination
is available
Check shielding of the cables
Check PE connection
Check bus load, reduce the
baud rate, if necessary
Check wiring of the system
bus
Check system bus
configuration
In all parameter sets, the "change
over parameter set" signal
(C0410/13, C0410/14) must be
connected with the same source
Contact Lenze
L