Herunterladen Diese Seite drucken

Alarm In Port (Female) - Sony PMS-500P Bedienungsanleitung

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

USER DATA port (male)
1
5
6
9
D-sub 9-pin port
Pin
Acronym
Meaning
1
NC (DCD)
(Data carrier detect)
2
RxD
Receive data
3
TxD
Transmit data
4
DTR
Data terminal ready
5
GND
Ground
6
DSR
Data set ready
7
RTS
Request to send
8
CTS
Clear to send
9
NC
Notes
• This port can be used as either an RS-232C or an RS-
485 interface. If this is used as an RS-485 interface,
pins 14 and 15 of the CAMERA SELECT port are
used for the RS-485 interface.
• Pins 4 and 6 have a short-circuit and pins 7 and 8 are
used as a flow control signal when set to the RS-
232C interface.
CAMERA CONTROL port (female)
8
1
15
9
D-sub 15-pin port
Pin
Acronym
Meaning
Tilt ↑
1
C1
Tilt ↓
2
C2
Pan →
3
C3
Pan ←
4
C4
5
C5
Zoom –
6
C6
Zoom +
7
C7
Focus –
8
C8
Focus +
9
C9
Iris –
10
C10
Iris +
11
C11
AUX1
12
C12
AUX2
13
GND
Ground
14
GND
Ground
15
GND
Ground

ALARM IN port (female)

5
1
9
6
D-sub 9-pin port
Pin
Meaning
1
Port 1
2
Port 2
3
Port 3
4
Port 4
5
Port 5
RELAY OUT port (female)
5
1
9
6
D-sub 9-pin port
Pin
Meaning
1
Port 1
2
Port 2
3
Port 3
4
Port 4
5
Port 5
Pin
Meaning
6
Port 6
7
Port 7
8
Port 8
9
Ground
Pin
Meaning
6
Port 6
7
Port 7
8
Port 8
9
Ground
A-9
Appendix
(GB)

Werbung